A.7.3 Modes

There are two modes of operation that may intersect: Redundant Mode and Automatic Mode.

A.7.3.1 Redundant Mode

Since the default mode is OFF, each converter including the backup converter must be

commanded into the Redundant Mode.

Polling on the high speed bus will not begin until the position assignments are made.

Command

Details

Redundant Mode:

<DEV/RED_xxx'cr' xxx = ON or OFF

Confirmation:

>DEV/RED_xxx'cr''lf']

Redundant Status:

<DEV/RED_'cr'

Confirmation:

>DEV/RED_xxx'cr''lf']

Note: The primary units must all be configured properly in redundant mode before redundant

mode is enabled on the backup unit.

Each converter's chain position must be initialized including the backup converter. The following

redundancy initialization command is only allowed if Redundancy Mode has been selected.

Command

Details

Initialize Command:

<DEV/ICT_xx_yy'cr'

Confirmation:

>DEV/ICT_xx_yy'cr''lf']

Initialize Status:

<DEV/ICT_'cr'

Confirmation:

>DEV/ICT_xx_yy'cr''lf']

xx = chain position = 01 to 12, or BU. Where BUselects the converter as the

backup.

yy = chain length for xx = BU (i.e. Backup converter) 01 to 12.

yy = unused if xx = 01 to 12 (i.e. chain converter)

Example 1:

The following command assigns the converter chain position "1".

<DEV/ICT_01'cr'

>DEV/ICT_01'cr''lf']

Example 2:

The following command assigns the receiving converter as the backup converter

in a 1:8 system.

<DEV/ICT_BU_08'cr'

>DEV/ICT_BU_08'cr''lf']

Important: It should be reiterated that only the converter physically located at the top of a

redundant rack should be assigned as the Backup unit. Likewise, assignment of chain positions in

a redundant rack should be made according to the physical allocation of each converter in the

rack (i.e. The top converter should be the Backup, the second converter should be assigned

chain position 1, the third converter position 2, etc.).