In the "Daisy Chain" configuration, the backup downconverter communicates with the

online units through the high-speed interface bus (HSB). The backup downconverter is able

to detect faults and reconfigure itself to replace the faulted downconverter. The HSB

interface is also used in the backup downconverter to monitor configuration changes made

to an online downconverter. Changes in frequency, gain, or polarity are immediately

entered into the backup table as well as information from new online units. The high-speed

bus does not interfere with the remote serial communication link access to any of the

converters in the chain.

The HSB (High Speed Bus) submenu is used to configure operation of the J3 HSB connector

provided on the optional Receive Switch Module (RSM) and Transmit Switch Module (TSM).

When an RSM or TSM is not configured for operation, the following message displays:

CONV #01 – NO DATA
HSB NO RESPONSE

Press ENTER or CLEAR to continue.

See Appendix B. REDUNDANT SYSTEM OPERATION for detailed information about using the

front panel menus for redundancy configuration and operation.

5.3.1.4

CONFIG: FAULTRECOVERY

Fault Recovery: Auto

Use the

▲ ▼ arrow keys to select Fault Recovery as Manual or Automatic, and then press

ENTER. The default operation is Auto.

5.3.1.5

CONFIG: COLDSTART

Cold Start = Disabled.


When redundancy is not active, use the

▲ ▼ arrow keys to select Cold Start as Enabled or

Disabled, and then press ENTER. The default operation is Disabled.

Cold Start Mode, if enabled, mutes the downconverter output signal for a pre-determined time

after power is applied to the downconverter – 15 minutes – to ensure that the reference

oscillator is stable.