A.7.4.8 packed maintenance status, A.7.4.9 packed utility status – Comtech EF Data DT-4500-A Series User Manual
Page 134
DT-4500-A Series Downconverters
Revision 1
Appendix A
MN-DT4500A
A–24
A.7.4.8 Packed Maintenance Status
Packed Maintenance Status: <DEV/PACRMS_'cr'
Confirmation:
>DEV/PACRMS_aabbccddeeeffgghhii'cr''lf']
where:
aa
= V15 scaled 123mV per count (0x00 - 0xFF)
bb
= V14 scaled 123mV per count (0x00 - 0xFF)
bc
= VCC scaled 39mV per count (0x00 - 0xFF)
dd
= V5D scaled 39mV per count (0x00 - 0xFF)
eee
= signed Temperature in degrees C (-10 to +60)
ff
= IFLO tune scaled 67mV per count (0x00 - 0xFF)
gg
= SUM tune scaled 54mV per count (0x00 - 0xFF)
hh
= COARSE tune scaled 78mV per count(0x00 - 0xFF)
ii
= FINE tune scaled 89mV per count (0x00 - 0xFF)
A.7.4.9 Packed Utility Status
Packed Utility Status:
<DEV/PACRUS_'cr'
Confirmation:
>DEV/PACRUS_abbcdeeffghhii'cr''lf']
where:
a
= 0=EIA-232, 1=EIA-485
bb
= Address in hex (01 to FF)
c
= 0 if Baud Rate 38400
= 1 if Baud rate 19200
= 2 if Baud rate 9600
= 3 if Baud rate 4800
= 4 if Baud rate 2400
= 5 if Baud rate 1200
d
= 0 if Data Format 8-N-1
= 1 if Data Format 7-E-2
= 2 if Data Format 7-O-2
ee
= Osc. Adjust in hex (00 to FF)
ff
= Slope Adjust times by 10 (00 to 10)
g
= Always 0, unused
hh
= LCD Contrast (0 to 30)
ii
= LCD Brightness (0 to 30)