A.7.4.8 packed maintenance status, A.7.4.9 packed utility status – Comtech EF Data DT-4500-A Series User Manual

Page 134

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Appendix A

MN-DT4500A

A–24

A.7.4.8 Packed Maintenance Status

Packed Maintenance Status: <DEV/PACRMS_'cr'

Confirmation:

>DEV/PACRMS_aabbccddeeeffgghhii'cr''lf']

where:

aa

= V15 scaled 123mV per count (0x00 - 0xFF)

bb

= V14 scaled 123mV per count (0x00 - 0xFF)

bc

= VCC scaled 39mV per count (0x00 - 0xFF)

dd

= V5D scaled 39mV per count (0x00 - 0xFF)

eee

= signed Temperature in degrees C (-10 to +60)

ff

= IFLO tune scaled 67mV per count (0x00 - 0xFF)

gg

= SUM tune scaled 54mV per count (0x00 - 0xFF)

hh

= COARSE tune scaled 78mV per count(0x00 - 0xFF)

ii

= FINE tune scaled 89mV per count (0x00 - 0xFF)

A.7.4.9 Packed Utility Status

Packed Utility Status:

<DEV/PACRUS_'cr'

Confirmation:

>DEV/PACRUS_abbcdeeffghhii'cr''lf']

where:

a

= 0=EIA-232, 1=EIA-485

bb

= Address in hex (01 to FF)

c

= 0 if Baud Rate 38400

= 1 if Baud rate 19200

= 2 if Baud rate 9600

= 3 if Baud rate 4800

= 4 if Baud rate 2400

= 5 if Baud rate 1200

d

= 0 if Data Format 8-N-1

= 1 if Data Format 7-E-2

= 2 if Data Format 7-O-2

ee

= Osc. Adjust in hex (00 to FF)

ff

= Slope Adjust times by 10 (00 to 10)

g

= Always 0, unused

hh

= LCD Contrast (0 to 30)

ii

= LCD Brightness (0 to 30)

Advertising