Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 102

Advertising
background image

Torch SeTup

3-54

powermax

65/85 Service Manual

45A Unshielded

Air flow rate - slpm/scfh

Aluminum

Hot

147 / 310

Cold

210 / 450

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

1

1.5

3.8

250

0.0

7400

126

11000

121

2

0.1

4400

127

9200

123

3

0.2

2800

129

6250

125

4

0.4

2100

132

4700

126

6

0.5

1050

135

2250

127

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

%

seconds

ipm

Volts

ipm

Volts

1/32 in

0.06

0.15

250

0.0

325

126

450

121

1/16 in

0.1

200

126

400

122

3/32 in

0.2

150

127

328

124

1/8 in

0.4

100

130

224

125

1/4 in

0.5

36

136

72

127

Advertising