Engine-driven generator recommendations

Generators used with the Powermax65 or Powermax85 should satisfy the following requirements:

CSA

• 1-phase, 50/60 Hz, 230/240 VAC
• 3-phase, 50/60 Hz, 200-600 VAC (480 VAC recommended for best performance)

CE

• 3-phase, 50/60 Hz, 380/400 VAC (400 VAC recommended for best performance)

Note: Based on the generator rating, age, and condition, adjust the cutting current as needed.

If a fault occurs while using a generator, turning the power switch quickly to OFF and then to ON again

(sometimes called a “quick reset”) may not clear the fault. Instead, turn OFF the power supply and wait 30 to

45 seconds before turning ON again.

Engine drive

rating

System output

current

Performance

(arc stretch)

20 kw

85 A

Full

15 kw

70 A

Limited

15 kw

65 A

Full

12 kw

65 A

Limited

12 kw

40 A

Full

8 kw

40 A

Limited

8 kw

30 A

Full