Extension cord specifications, Extension cord specifications -12, Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 44

Advertising
background image

Power SuPPly SetuP

2-12

powermax

65/85 Service Manual

Extension cord length

< 10 ft

(< 3 m)

10 – 25 ft

(3 – 7.6 m)

25 – 50 ft

(7.5 – 15 m)

50 – 100 ft

(15 – 30 m)

100 – 150 ft

(30 – 45 m)

65 A CSA

Input voltage

(VAC)

Phase AWG (mm

2

) AWG (mm

2

) AWG (mm

2

) AWG (mm

2

) AWG (mm

2

)

200240

1

8 (10)

8 (10)

8 (10)

6 (16)

4 (25)

480

1

12 (4)

12 (4)

12 (4)

10 (6)

10 (6)

200240

3

10 (6)

10 (6)

10 (6)

8 (10)

6 (16)

400/480

3

12 (4)

12 (4)

12 (4)

12 (4)

12 (4)

600

3

12 (4)

12 (4)

12 (4)

12 (4)

12 (4)

65 A CE

Input voltage

(VAC)

Phase

mm

2

mm

2

mm

2

mm

2

mm

2

380

3

4

4

4

4

4

400

3

4

4

4

4

4

85 A CSA
Input voltage

(VAC)

Phase AWG (mm

2

) AWG (mm

2

) AWG (mm

2

) AWG (mm

2

) AWG (mm

2

)

200240

1

6 (16)

6 (16)

6 (16)

4 (25)

2 (35)

480

1

10 (6)

10 (6)

10 (6)

8 (10)

8 (10)

200240

3

8 (10)

8 (10)

8 (10)

6 (16)

4 (25)

400/480

3

10 (6)

10 (6)

10 (6)

10 (6)

10 (6)

600

3

10 (6)

10 (6)

10 (6)

10 (6)

10 (6)

85 A CE
Input voltage

(VAC)

Phase

mm

2

mm

2

mm

2

mm

2

mm

2

380

3

6

6

6

6

6

400

3

6

6

6

6

6

Extension cord specifications