TroubleshooTing and sysTem TesTs

5-30

powermax

65/85

Service Manual

Fault

code

Description

(System test number)

Power

LED

Fault

LED

Fault

icon

Solutions

3-41-0 Drive fault

On

On

If an activation signal is sent to a device and

the device does not activate (machine motion

relay or in-rush relay for example) this fault will

occur.

3-42-0 5 or 24 VDC fault (Test 5)

The 5 or 24 VDC supply from the flyback

circuit is out of range.

3-42-1 18 VDC fault

The 18 VDC supply from the flyback circuit is

out of range.
• Replace the power board.

3-43-0 Inverter capacitors

unbalanced (Test 2)

Voltage across one or both inverter caps is

more than 25% different than nominal.
• CSA units have a 760 VDC bus voltage.
• Nominal is 380 VDC for each cap.
• Fault condition: < 275 or > 485 VDC

across either capacitor.

• CE units at 400 VAC have a 560 VDC bus

voltage.

• Nominal is 280 VDC for each cap.
• Fault condition: <200 or> 360 VDC across

either capacitor.

• Test the IGBT module.
• Test the inverter capacitors. (2200µF)

3-44-1 PFC over current

High current in the PFC/Boost circuit.
• Test the PFC IGBT.
• Replace it if faulty.
• If necessary, replace the power board.