TroubleshooTing and sysTem TesTs

powermax

65/85

Service Manual

5-31

Fault

code

Description

(System test number)

Power

LED

Fault

LED

Fault

icon

Solutions

3-51-1 Inverter saturation fault (the

inverter is over current)

On

On

Upper and lower inverter IGBTs are gating

(being activated) in phase rather than 180°

out of phase.
• Test the two inverter IGBTs in the module.
• Replace the module if either is faulty.
• If necessary, replace the power board.

3-52-0 Shoot through

3-60-0 Power board

The DSP does not recognize the power

board. The code is for future machines where

the current DSP board will not work with

future power boards.

3-70-0 Internal serial communications

fault

There is a fault with the communication

between the DSP and Power board.
• Check the board connector.
• If necessary, replace either the DSP or

Power board.