TroubleshooTing and sysTem TesTs

5-6

powermax

65/85

Service Manual

Sequence of operation

Power OFF

• Connect the gas supply to the air fitting on the power supply.
• Connect the work lead to the power supply and workpiece.
• Connect the torch to the power supply.
• Plug in the power supply and make sure incoming power is

ON if using a line-disconnect box.

• Set the ON/OFF switch (S1) to ON (I).

• Set the power switch (S1) to OFF (O).

• The electronic regulator deactivates.
• The gas flow stops.

• The arc extinguishes.
• Gas continues to flow for 20 seconds.

• Drag the torch lightly across the

workpiece to make a cut.

• The workpiece drops after the cut.
• Release the plasma start trigger on the

hand torch or the remote start switch for

the machine torch.

• The electronic regulator activates.
• The gas flow starts.
• The cutting arc starts.

• Position the torch over the workpiece.
• Pull the plasma start trigger on the hand

torch or press the remote start switch for

the machine torch.

• The green power ON LED illuminates, indicating the system is

ready for operation.

• The fault LED should be off (see Troubleshooting guide and

Fault codes in this section for more information).

• Set the amperage adjustment knob to the desired output

current based on the thickness of the metal to be cut.

Note: The gas pressure automatically adjusts for optimal

cutting based on the selected settings.

• Set the mode switch to the desired mode for cutting or

gouging.

Advertising