Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 66

Advertising
background image

Torch SeTup

3-18

powermax

65/85 Service Manual

Note: The cover on the machine interface receptacle prevents dust and moisture from damaging the receptacle

when not in use. This cover should be replaced if damaged or lost (part number 127204).

See the Parts section for more information.

Installation of the machine interface cable must be performed by a qualified service technician. To install a machine

interface cable:
1. Turn OFF the power and disconnect the power cord.
2. Remove the machine interface receptacle’s cover from the rear of the power supply.
3. Connect the Hypertherm machine interface cable to the power supply.
4. If you are using a cable with a D-sub connector on the other end, plug it into the appropriate pin connector on the

torch height controller or CNC. Secure it with the screws on the D-sub connector.

If you are using a cable with wires and spade connectors on the other end, terminate the machine interface

cable inside the electrical enclosure of listed and certified torch height controllers or CNC controllers to prevent

unauthorized access to the connections after installation. Verify that the connections are correct and that all live

parts are enclosed and protected before operating the equipment.

Note: The integration of Hypertherm equipment and customer-supplied equipment including interconnecting cords

and cables, if not listed and certified as a system, is subject to inspection by local authorities at the final

installation site.

The connector sockets for each type of signal available through the machine interface cable are shown in the figure

below. The table provides details about each signal type.

Advertising
This manual is related to the following products: