TroubleshooTing and sysTem TesTs

5-52

powermax

65/85

Service Manual

Test 9 – Electronic regulator

Symptom: Air flows continuously through the torch.
1. Turn off the machine and disconnect power.
2. Disconnect the electronic regulator control cable (J4 for CSA, J6 for CE) from the power board.

• If air continues to flow, replace the electronic regulator.
• If the air stops flowing, verify the DSP board by replacing it with a known good one. If the DSP board is not the

problem, replace the power board.

Pressure sensor

J5 (CSA), J7 (CE)

Fan

J3 (CSA), J5 (CE)

Electronic regulator

J4 (CSA), J6 (CE)

Inverter temperature sensor

J2 (CSA), J4 (CE)