Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 81

Advertising
background image

Torch SeTup

powermax

65/85 Service Manual

3-33

65A Shielded

Air flow rate - slpm/scfh

Aluminum

Hot

160 / 340

Cold

220 / 470

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

2

1.5

3.8

250

0.1

8800

121

10300

122

3

0.2

7400

124

8800

124

4

0.5

6000

126

7350

125

6

3200

130

4400

128

8

0.7

1950

133

2750

130

10

4.5

300

1200

136

1650

132

12

1.2

1000

138

1330

136

16

Edge Start

650

143

800

141

20

380

147

560

145

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

%

seconds

ipm

Volts

ipm

Volts

1/16 in

0.06

0.15

250

0.1

365

121

428

121

1/8 in

280

124

336

124

1/4 in

0.5

105

131

152

128

3/8 in

0.7

50

135

68

131

1/2 in

0.18

300

1.2

35

139

48

138

5/8 in

Edge Start

26

143

32

141

3/4 in

16

146

24

144

Advertising