IGBT device test using the Hypertherm tester

Using the Hypertherm IGBT tester, press and hold the switch in the desired position to perform each test described in

the following table.

Switch

LED

Position

Fail

Pass

Battery This may mean

Corrective action

Left

X

-

-

IGBT is short-circuited

Replace IGBT

Left

-

X

-

IGBT passed the short-circuit test

None

Left

-

-

X

Battery below 8 V

Replace battery

Left

-

-

-

Dead battery

Replace battery

Right

X

-

-

IGBT is open

Replace IGBT

Right

-

X

-

IGBT passed the open test

None

Right

-

-

X

Battery below 8 V

Replace battery

Right

-

-

-

Dead battery

Replace battery

Troubleshoot the Hypertherm IGBT tester

1. Inspect the leads and the IGBT tester for damage.
2. Verify that the battery voltage is greater than 8 V.
3. Test the IGBT Tester, itself, as shown below. If the results do not match the table, replace the lead connections.

Connect leads

Short test

Open test

None

Pass

Fail

Red to Black

Fail

Pass