Replace the power cord (200 – 480 V 1-phase CSA)

To operate your Powermax on 1-phase power, you will need to install an appropriate power cord.

Strip and prepare the power cord wires as shown below.

L1

L2

Ground (GND)

#10

14.5 in (368 mm)

6 in (152 mm)

L1

L2

Power switch

Ground screw

Route lead through

strain relief and tighten

Caution: When using the Powermax85 CSA model power supply (CE model is 3-phase

only) with a 1-phase power source, replace the supplied power cord with a

6 AWG (16 mm

2

) 3-wire power cord. The power cord must be connected by

a licensed electrician.

Install a plug on the power cord (CSA)

Use a plug that meets national and local electrical codes. The plug must be connected to the power cord by a licensed

electrician.