Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 137

Advertising
background image

TroubleshooTing and sysTem TesTs

powermax

65/85

Service Manual

5-11

Measure resistance

from

200 – 600 V CSA power

board location

400 V CE power

board location

Approximate

values

Work lead to nozzle

J26 to black wire

J27 to black wire

230 kΩ

Work lead to electrode

J26 to red wire

J27 to red wire

15 kΩ

Electrode to nozzle

red wire to black wire

red wire to black wire

230 kΩ

Output to ground

> 20 MΩ

If no problems were found during the visual inspection or the initial resistance check, and the power supply still does not

operate correctly, see the Troubleshooting guide.

Note: The Troubleshooting guide provides most probable causes and solutions. Study the system wiring diagram

and understand the theory of operation before troubleshooting. Before purchasing any major replacement

component, verify the problem with Hypertherm Technical Service or the nearest Hypertherm repair facility.

Black wire

Red wire

J28 CSA

J29 CE

J26 CSA

J27 CE

WORK

LEAD

Advertising
This manual is related to the following products: