Torch SeTup

powermax

65/85 Service Manual

3-41

Low Speed FineCut

Air flow rate – slpm/scfh

Mild Steel

Hot

155 / 330

Cold

215 / 460

Metric

Material

Thickness

Current

Torch-

to-Work

Distance

Initial Pierce Height

Pierce Delay

Time

Recommended

Cut Speed

Voltage

mm

A

mm

mm

%

seconds

(mm/min)

Volts

0.5

30

1.5

2.25

150

0.0

3800

69

0.6

3800

68

0.8

0.1

3800

70

1 *

40

0.2

3800

72

1.5 *

0.4

3800

75

2

45

3700

76

3

0.5

2750

78

4

1900

78

English

Material

Thickness

Current

Torch-

to-Work

Distance

Initial Pierce Height

Pierce Delay

Time

Recommended

Cut Speed

Voltage

A

inches

inches

%

seconds

ipm

Volts

26GA

30

0.06

0.09

150

0.0

150

70

24GA

150

68

22GA

0.1

150

70

20GA

150

71

18GA

40

0.2

150

73

16GA *

0.4

150

75

14GA *

45

150

76

12GA

0.5

120

78

10GA

95

78

*Not a dross-free cut.