TroubleshooTing and sysTem TesTs

5-48

powermax

65/85

Service Manual

Test 6 – Torch stuck open (TSO)

Symptom: No fault occurs at power-up but an 0-30 fault displays on the operator screen when attempting to fire the

torch.

Confirm that all of the proper consumables are installed in the torch.

In an idle (no start signal) working system with the torch and consumables installed, there should be continuity between

the dual black wires connected to the center post of the pilot arc IGBT and the red wire connecting to J28. With gas

flowing through the torch (gas test mode 1) there should be very high resistance between those two points.

Note: To set the system to gas test mode, display the service screen (refer to page 5-21 Displaying the service

screen), move the cursor to “G” (gas), and use the adjustment knob to toggle to “1” (gas test mode).

WORK

LEAD

J26

J28

WORK

LEAD

J26

J28

Gas test mode 0

Gas test mode 1

<5 Ω

>10 kΩ

Continuous with

the nozzle or torch

outer body

Continuous with

system negative