5-27

Fault

code

Description

(System test number)

Power

LED

Fault

LED

Fault

icon

Solutions

0-98-0 Internal communication

failure
The control board and the

DSP are not communicating.

On

On

• Perform a cold restart.
• Confirm that the connecting ribbon cable is

installed properly between the control board

and the DSP board.

0-99-0 System hardware fault

(service required)
Indicates a major fault with

the system.

On

On

• Display the service screen.
• A qualified service technician must service

the system. Contact your distributor or

authorized repair facility.

1-nn-n

These fault codes usually relate to the DSP board and can only be seen on the service screen.

Fault

code

Description

(System test number)

Power

LED

Fault

LED

Fault

icon

Solutions

1-00-0 Digital signal processor fault

On

On

These are internal processor checks and are

not likely to be caused by a hardware failure.
• Perform a cold restart.
If that doesn’t fix the problem, it is possible

that the DSP or Power board have failed.

1-10-0 A/D converter fault
1-20-0 I/O fault