TroubleshooTing and sysTem TesTs

5-54

powermax

65/85

Service Manual

Test 11 – Fan

Symptom: The fan does not operate properly.

Note: Wear proper PPE protection before testing powered equipment.
1. Remove the inverter temperature sensor plug from J2 in CSA units or J4 in CE units.
2. Place a jumper between Pin 1 and Pin 3 of the connector (J2/J4) on the power board.
3. Remove the white cover from the fan control cable at J3 for CSA units or J5 for CE units.
4. Turn the machine on.
5. With the fan control cable connected to J3 for CSA units and J5 for CE, measure the DC voltage between Pin 1

and Pin 4 in the plug.
a. If the voltage is 48 VDC (±5%), replace the fan.
b. If the voltage is not correct:

- Remove the fan control cable and re-measure the DC voltage on the power board connector between Pin

1 and Pin 4 of J3/J5.

- If the voltage is 48 VDC, replace the fan. Otherwise, perform Test 6 – Flyback circuit above.

c. If the system passes the flyback circuit test:

- If the voltage between Pin 1 and Pin 3 (J3 / J5) is 0 VDC, replace the DSP board.
- If the voltage is greater than 0, replace the power board.