Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 155

Advertising
background image

TroubleshooTing and sysTem TesTs

powermax

65/85

Service Manual

5-29

3-nn-n

These fault codes relate to the power board and can only be seen on the service screen.

Fault

code

Description

(System test number)

Power

LED

Fault

LED

Fault

icon

Solutions

3-00-0 DC bus voltage (Test 5)

DC bus voltage is out of

range.

On

On

• Inspect the PFC Boost circuitry (CSA)
• Test the PFC Boost IGBT (CSA)

3-10-0 Fan speed (Test 11)

The fan speed is below the

minimum speed.

• Clean the fan assembly.

3-10-1 Fan (Test 11)

• Check the associated wiring.
• If necessary, replace the fan assembly.

3-11-0 PFC module temp sensor

open (Test 4)

• Check the associated wiring.
• If necessary, replace the PFC/Boost IGBT

module.

3-11-1 PFC module temp sensor

shorted (Test 4)

• Check the associated wiring.
• If necessary, replace the PFC/Boost IGBT

module.

3-11-2 PFC module temp sensor

circuit error

• Check the temperature circuit on the power

board. If Test 4 is good, replace the power

board.

3-20-0 Fill valve (Test 9)

Indicates that the Fill Valve is

not connected.

• Check the associated wiring.
• If necessary, replace the electronic

regulator. (Kit 228687)

3-20-1 Dump valve (Test 9)

Indicates that the Dump Valve

is not connected.

• Check the associated wiring.
• If necessary, replace the electronic

regulator. (Kit 228687)

3-20-2 Valve ID (Test 9)

The DSP does not recognize the electronic

regulator.

3-20-3 Electronic regulator is

disconnected (Test 9)
The electronic regulator is not

drawing current.

• Inspect the associated wiring, particularly

the 7-pin connector.

• If necessary, replace the electronic

regulator. (Kit 228687)

Advertising
This manual is related to the following products: