Replace the work lead, Replace the work lead -11, Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 193

Advertising
background image

Component ReplaCement

powermax

65/85

Service Manual

6-11

Replace the work lead

Work lead

receptacle

on power supply

Keyed opening at

top of

receptacle

1. Turn OFF the power.
2. Remove the old work lead from the front of the power supply. Turn the work lead connector counterclockwise

approximately 1/4 turn.

3. Pull the work lead connector out of the receptacle.
4. Insert the new work lead connector into the receptacle.

Note: The receptacle is keyed. Align the key on the work lead connector with the opening at the top of the

receptacle on the power supply.

Caution: Make sure you use a work lead that is appropriate for your power supply.

Use a 65 A work lead with the Powermax65. Use an 85 A work lead with the

Powermax85. The amperage is marked near the rubber boot of the work lead

connector.

Caution: Ensure the work lead is fully seated in the receptacle to prevent overheating.

5. Push the work lead connector all the way into the receptacle on the power supply and turn clockwise, approximately

1/4 turn, until the connector is fully seated against the stop in order to achieve an optimal electrical connection.

Advertising
This manual is related to the following products: