TroubleshooTing and sysTem TesTs

5-28

powermax

65/85

Service Manual

2-nn-n

These fault codes usually relate to either the DSP or the power board and can only be seen on the service screen.

Fault

code

Description

(System test number)

Power

LED

Fault

LED

Fault

icon

Solutions

2-00-0 Analog to Digital (A/D)

converter value out of range

On

On

• Perform a cold restart.
If that doesn’t fix the problem, it is possible

that the DSP or Power board have failed.

2-01-0 Auxiliary switch disconnected

• Check the auxiliary switch cable.
• Perform Test 12.

2-10-0 Inverter module temp sensor

open (Test 4)

• Check the associated wiring.
• Check the resistance across the thermistor.

It should be about 10 kΩ at room

temperature.

If no problems are found, it is possible that

the inverter heat sink temperature sensor

assembly (228805) has failed.

2-10-1 Inverter module temp sensor

shorted (Test 4)

2-11-0 Pressure sensor open (Test

10)

• Check the associated wiring.
• If necessary, replace the pressure sensor

(kit 228689)

2-11-1 Pressure sensor shorted

(Test 10)

2-20-0 Torch ID

The DSP does not recognize

the torch.

• Confirm that the torch is seated properly in

the connector.

• Inspect the connector for the proper pin-

out.