Test 1 – voltage input, Test 1 – voltage input -39, Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 165

Advertising
background image

TroubleshooTing and sysTem TesTs

powermax

65/85

Service Manual

5-39

BLK

BLK

J13

Test 1 – Voltage input

Symptom: Voltage fault (0-60-0, -1 or -2)

• Check the line voltage at the power switch (S1).
• Check the input voltage to the input diode bridge.

- The AC voltage between any 2 input wires should equal the line voltage.

• If there is proper voltage to the power switch, and low voltage to the input diode, replace the power switch.
• Check the output voltage of the input diode bridge.

- Output VDC = Line Voltage x 1.414 VDC.

Note: All values are ±15%.

Three phase

L1

Black (CSA)

Brown (CE)

L2

White (CSA)

Black (CE)

L3

Red (CSA)

Gray (CE)

PE

Green (CSA)

Green/Yellow (CE)

LV

LV/1.732

LV

LV

LV X 1.414

• If there is a fault and the diode bridge output value is correct:

- Display the service screen and confirm that the value “VL” is ±15% of AC line voltage.

LV = incoming line voltage

• If there is a fault and the “VL” value is correct:

- Verify the DSP board by replacing it with a known good board.
- If DSP board is not the problem, replace the power board and the PFC IGBT (CSA units only).

Single phase

L

Black (CSA)

N

White (CSA)

PE Green (CSA)

Advertising