5-35

Problem

Meaning

Causes

Solution

Arc goes out while

cutting or intermittently

will not fire.

The arc lost contact

with the workpiece.

• The work lead

or work lead

connection may

be faulty.

• The material

being cut may

require the use of

continuous pilot

arc mode.

• If you are cutting expanded metal, grate,

or any metal with holes, set the mode

switch to continuous pilot arc mode.

• Check for loose connections at the work

clamp and at the power supply.

• Reposition the work lead on the

workpiece.

• Clean the cutting surface to ensure a

better connection with the work lead.

Faulty fan.

• The fan could be

overloading the

flyback circuit.

• Perform Tests 5 and 11.

The cut quality is poor

or the cut does not sever

the metal.

The consumables

are worn, there is

a poor work lead

connection, the

output from the

power supply is

too low, the power

board is producing

low current, or the

selected cutting

mode is incorrect..

• The consumables

need to be

replaced

• Inspect the consumables and replace if

necessary.

• The work lead

may be damaged

or not properly

connected to the

work piece

• Inspect the work lead for damage.

Reposition it and clean the work surface

to ensure good contact.

• The amperage

adjustment knob

may be set too

low.

• Increase the amperage as needed.

• The power board

(PCB3) may be

faulty.

• Perform Tests 1, 2, and 3 and replace

any faulty components.

The cutting mode

switch is in the

wrong position

for the cutting

operation.

• Ensure the cutting mode switch is in the

correct position.

• Faulty pilot arc

IGBT.

• Turn the power OFF, remove the

consumables, and check the resistance

between the cathode and the work

clamp. If the resistance is less than

5 kΩ, check the resistance across the

pilot arc IGBT (two screws on 08). If the

resistance is less than 5 kΩ, replace the

pilot arc IGBT.