Powermax – Hypertherm Powermax65 Service Manual Rev.1 User Manual

Page 79

Advertising
background image

Torch SeTup

powermax

65/85 Service Manual

3-31

65A Shielded

Air flow rate - slpm/scfh

Mild Steel

Hot

160 / 340

Cold

220 / 470

Metric

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

mm

mm

mm

%

seconds

(mm/min)

Volts

(mm/min)

Volts

2

1.5

3.8

250

0.1

6050

124

7000

121

3

0.2

5200

125

6100

123

4

0.5

4250

125

5100

124

6

2550

127

3240

127

8

1700

129

2230

128

10

4.5

300

0.7

1100

131

1500

129

12

1.2

850

134

1140

131

16

6.0

400

2.0

560

138

650

136

20

Edge Start

350

142

450

142

25

210

145

270

145

English

Material

Thickness

Torch-

to-Work

Distance

Initial Pierce

Height

Pierce

Delay

Time

Best Quality Settings

Production Settings

Cut Speed

Voltage

Cut Speed

Voltage

in

in

%

seconds

ipm

Volts

ipm

Volts

16GA

0.06

0.15

250

0.1

260

123

294

121

10GA

190

125

224

123

3/16 in

0.2

140

126

168

125

1/4 in

0.5

90

127

116

127

3/8 in

0.7

45

130

62

129

1/2 in

0.18

300

1.2

30

135

40

132

5/8 in

0.24

400

2.0

23

138

26

136

3/4 in

Edge Start

15

141

19

141

7/8 in

12

143

14

143

1 in

8

145

10

145

Advertising