Component ReplaCement

powermax

65/85

Service Manual

6-5

Replace the power cord

For wire sizes, see Extension cord specifications in Section 2, Power Supply Setup.

Replace the power cord (200 – 600 V 3-phase CSA, 400 V 3-phase CE)

This section describes the procedures for replacing the power cord on 3-phase power supplies.

Remove the existing 3-phase power cord

1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply.
2. Remove the power supply cover and Mylar barrier. Refer to page 6-2 Remove and replace the power supply

cover and Mylar

®

barrier.

3. Loosen the set screws that secure the three power wires to the top of the power switch.

Note: For CSA models, use a #2 Phillips screwdriver. For CE models, use a #1 Phillips screwdriver.

L1

L2

Power switch

Ground screw

Strain relief

retention nut

L3

Strain relief nut

inside power

supply