TroubleshooTing and sysTem TesTs

powermax

65/85

Service Manual

5-49

Before continuing, turn OFF the power.

If the resistance value is always less than 100 Ω, remove the torch and recheck the resistance. If the value is still less

than 100 Ω:

• Use an IGBT tester to check for a shorted pilot arc IGBT.
• Replace the pilot arc IGBT if it is shorted.

If the resistance is always greater than 100 Ω:

• Replace all consumables and recheck.
• If the resistance is correct (<100 Ω) the old consumables are bad.
• If the resistance is still greater than 100 Ω, measure the resistance in the torch between the pilot arc wires (Pin

1 or 2) and negative arc power (the center connection).

• If the resistance is still too high, replace the torch and lead.

Note: The retaining cap should be snug but not over-tightened.

All values are ±15%

Check the function of the pilot arc IGBT:

• Turn the machine off and disconnect power.
• Install a jumper wire from the work lead (J26 for CSA, J27 for CE) to the pilot arc IGBT (dual black wires).
• Reconnect power and turn on the machine.
• Attempt to fire the torch.
• If the torch fires, replace the pilot arc IGBT.

WORK

LEAD

J26

J28

Install a test

jumper here

Advertising