6 – Power Supply Component Replacement

Figure 27

Reattach the front panel

1. Push the front panel into the base of the power supply until it snaps into place.

2. Tighten the retaining screw to 23.0 kg∙cm (20 inch∙pounds). See Figure 26 on page 102.

3. Reconnect the control board’s ribbon cable to the power board at J7. Make sure the latches are folded up to hold the

connector in place.

4. Tighten the strain relief nuts on the torch lead and work lead.

5. Put the power supply cover back in place. See Install the power supply cover on page 99.