Powermax30 AIR Service Manual 808850

67

5 – Troubleshooting and System Tests

The air inlet filter on the internal compressor
is completely clogged.

For the compressor’s air inlet filter to
trigger this LED fault, the filter would
have to be so blocked that no air can
flow through it.

6. Replace the compressor’s air inlet filter. See

Replace the air inlet filter in the internal
compressor
on page 165.

One of the following internal components is
faulty and needs to be replaced:

Internal compressor

Compressor-driver board

Power board

7. Systematically check the internal compressor,

the compressor-driver board, and the power
board to determine which component needs to
be replaced. Perform

Test 9 – internal

compressor, compressor-driver board, and
power board
on page 91.

The internal compressor LED and the temperature LED blink
alternately when the machine is powered ON.

Possible causes

Possible solutions

The system was powered on with the torch
trigger being pulled.

The start circuit is stuck closed.

Release the torch trigger and reset the
system by turning it OFF (O) and then
turning it ON (I) again. The system
automatically disables itself when the power
supply is turned on while the torch trigger is
pulled.

Perform

Test 6 – plasma start on page 87.

The internal compressor LED and the temperature LED illuminate while
the machine is powered ON and the torch trigger is pulled.

Possible causes

Possible solutions