Powermax30 AIR Service Manual 808850

63

5 – Troubleshooting and System Tests

Troubleshooting guide

This guide provides the most common causes and solutions.

Before troubleshooting, study the

Powermax30 AIR schematic on page 222 and understand the Theory of operation

on page 55.

Before purchasing any major replacement component, verify the problem with Hypertherm Technical Service or the
nearest Hypertherm repair facility listed in the front of this manual.

See

System tests on page 73 for detailed test procedures.

Power LED faults

The ON/OFF power switch is set to ON (I),
but the power ON LED does not illuminate.

Possible causes

Possible solutions

The system has no incoming voltage or an
improper incoming voltage.

The power cord, power switch, or power
board is faulty.

Make sure the electrical power is connected
to an appropriately sized circuit.

Make sure the system did not trip the circuit
breaker.

Perform

Test 1 – voltage input on page 78.

The power ON LED illuminates, but no fault LEDs illuminate, and no gas
flows when you pull the torch trigger.

Possible causes

Possible solutions

The start signal is not reaching the control
board due to:

Damaged torch or torch lead

Faulty power board

OR

Faulty control board

Inspect the torch and torch lead, and
replace if necessary.

Make sure the control board start LED
illuminates when you pull the torch trigger. If
it does not, perform

Test 6 – plasma start on

page 87.

AC

AC

O

AC