6 – Power Supply Component Replacement

Install the fan

1. Orient the fan

so that the red-and-black wires extend from the bottom-right corner of the fan (the side closest to

the front panel).

2. Loosely install the 4 retaining screws. Use the screws included in the kit if needed.

3. Once all 4 retaining screws are installed, tighten them to 11.5 kg∙cm (10 inch∙pounds).

4. Orient the new fan plenum

so that the wider end is at the bottom, and snap it onto the fan. See

Figure 70.

5. Route the fan’s red-and-black wires through the notch in the top of the center panel that is labeled “FAN”

. The

notch is above the air filter

.

6. Attach the connector for the red-and-black wires to J5 on the power board.

Figure 70

7. Complete the following procedures:

a. See Install the power supply cover on page 99.

b. Reconnect the power cord, and set the power switch to ON (I).