6 – Power Supply Component Replacement

3. On the fan side of the power

supply, remove the ground wire
screw

from the base of the

magnetics assembly.

4. Make sure the air filter’s drain

hose

is disconnected from the

hole in the bottom of the base.

It is normal to see water in the
drain hose and in the air filter
bowl. Remove any water that
spills inside the power supply
before operating the system
again.

5. Use an 8 mm (5/16 inch) nut driver

to remove the nut that attaches the
ring terminal for the output
inductor’s white wire to the stud
labeled “WHT”

.