5 – Troubleshooting and System Tests

Error LED

The number of times the Error LED blinks indicates the problem detected. Each blink is a half-second long, and each
series of blinks is separated by a 2-second pause. See

System tests (below) for detailed test procedures.

Table 5

System tests

You can use either the ground clip near the top of the rear panel

or the ground screw on the heatsink

(marked by

the ground symbol on the power board) for any tests that require the multimeter to be attached to ground.

Figure 5 – Grounding options

Number of
blinks

Problem

Solution

3

Faulty power board or
control board

• Perform

Test 3 – VBUS and voltage balance on power board on

page 82. If any of the values are incorrect, replace the power board.

• Perform

Test 2 – power board voltage checks on page 80. If any of

the values for pins

5, 7, or 12 are incorrect, remove the control board

and test again. If the values are correct, replace the control board.

• If the values for pins

5, 7, or 12 are correct when you perform

Test 2 – power board voltage checks on page 80 but any other
values from Test 2 are incorrect, replace the power board.

4

Faulty fan, solenoid valve, or
power board

• Perform

Test 4 – solenoid valve on page 84 and Test 8 – fan on

page 90. If the solenoid valve test and the fan test both pass,
replace the power board. If Test 4 fails, replace the solenoid valve; if
Test 8 fails, replace the fan.

6

Inverter saturation

• Install new consumables in the torch. If you continue to see this error

code, replace the power board.

1

2

1

2

Advertising