Powermax30 AIR Service Manual 808850

2 – Power Supply Setup

CE power cords

CE configurations ship without a plug on the power cord. To operate at 230 V (CE), obtain the correct plug for your unit
and location and have it installed by a licensed electrician.

Install a plug on the power cord

1. Strip back the cord insulation to separate wires 3, 5, and 6.

2. Remove each wire’s insulation to allow good contact with the plug terminals.

3. Make the connections.

4. Reinstall the outer shell and cord grip, and tighten the cord grip’s screws until snug. Do not overtighten.

1

2

3

4

5

6

1

Cord grip

2

Outer shell

3

To line 1 terminal (brown)

4

230 V (CE) plug

5

To line 2 terminal (blue)

6

To ground terminal (green/yellow)