Timing chart for torch start – Hypertherm Powermax30 AIR Service Manual User Manual

Page 221

Advertising
background image

Powermax30 AIR Service Manual 808850

221

9 – Wiring Diagrams

Timing chart for torch start

Idle

Compressor

pressurizes

(350 ms)

Gas

solenoid opens

(15 ms)

Inverter on

until pilot arc

established

Transfer

(when work lead

current > 0.4 A)

Cutting

(steady state)

Torch

trigger released

Idle

Start signal (torch trigger) ON/OFF

(control board Start LED ON/OFF)

Internal compressor ON/OFF

Pilot arc IGBT ON/OFF

Gas solenoid ON/OFF

Inverter output ON/OFF

Control board Transfer LED ON/OFF

(system is cutting)

Postflow

(5–20 seconds)

Postflow

(5–20 seconds)

User-set current

Pilot arc current = 15 A

Transfer threshold: 1.6 A