5 – troubleshooting and system tests, Figure 13, Torch start – Hypertherm Powermax30 AIR Service Manual User Manual

Page 83

Advertising
background image

Powermax30 AIR Service Manual 808850

83

5 – Troubleshooting and System Tests

6. Measure the voltage from W to R. See Figure 13.

a. Position the test hooks on W and R on the power board.

b. Turn the power ON (I).

c. The multimeter should read 375 VDC.

If you get a value other than 375 VDC, multiply the reading by 0.00601 to convert it to millivolts. Test pin 21 on J7.
See

Test 2 – power board voltage checks on page 80. If the values match, it is a normal reading.

7. Measure the voltage from W to B.

a. Turn the power OFF (O).

b. Move the test hooks to W and B.

c. Turn the power ON (I).

d. This value should be 187.5 VDC or one-half of the value found in step 6.

8. Measure the voltage from R to B.

a. Turn the power OFF (O).

b. Move the test hooks to R and B.

c. Turn the power ON (I).

d. This value should be 187.5 VDC or one-half of the value found in step 6.

9. The values found in step 7 and step 8 should be approximately equal. If they differ by more than 30 V, replace the

power board.

Figure 13

WORK LEAD (BLK)

BLK

BLK

TORCH

START

AC

AC

R

w

step 8

step 7

step 6

Advertising