Hypertherm Powermax30 AIR Service Manual User Manual

Page 171

Advertising
background image

Powermax30 AIR Service Manual 808850

171

6 – Power Supply Component Replacement

Install the new rear panel

1. Install the power cord through the new rear panel. See Install the power cord and strain relief on page 114.

2. Push the new rear panel into the base until it snaps into place.

3. Make sure the hole in the ground wire clip is aligned with the screw holes in the rear panel and the power supply’s

center panel.

4. Tighten the retaining screw to 23.0 kg∙cm (20 inch∙pounds).

5. Align the rear panel so the rectangular box

on the inside of the panel slides over the heatsink

in the power

supply.

The power board and the wires from the power cord are hidden in

Figure 82 in order to

show the heatsink and the inside of the rear panel.

6. Press the power switch

into the new rear panel with the ON (I) label at the top of the switch. You should hear the

switch snap into place.

Figure 82