5 – troubleshooting and system tests figure 1, Torch start blk blk, Torch start – Hypertherm Powermax30 AIR Service Manual User Manual

Page 61

Advertising
background image

Powermax30 AIR Service Manual 808850

61

5 – Troubleshooting and System Tests

Figure 1

6. If you do not find any problems during the visual inspection or the initial resistance check, and the power supply is still

not operating correctly, see

Troubleshooting guide on page 63.

WORK LEAD (BLK)

AC

AC

R

w

TORCH

START

BLK

BLK

B

TORCH

START

J22

WORK LEAD (BLK)

J16, red