5 – Troubleshooting and System Tests
Table 6
All values can be ±10%.
CAUTION!
Do not use -VBUS (W) as ground. Doing so could destroy the power supply. Instead ground to either
the ground wire clip on the rear panel or to the heatsink. See Figure 5 on page 73.
J7 pin number to
ground
Test
Expected value
19
VACR (rectified AC line voltage)
0.86 V at 120 line voltage
1.87 V at 230 line voltage
21
VBUS (DC bus voltage)
2.28 VDC at 375 VBUS
18
IPFC (input current)
< 0.1 VDC
20
IFB (output current)
< 0.1 VDC
22
ITF (transfer current)
< 0.1 VDC
5
3.3 VDC
3.3 VDC ±10%
7
5 VDC
5 VDC ±10%
12
24 V sense pin
2.2 VDC ±10%
16
Start signal
3.2 VDC closed
0 VDC open