Powermax30 AIR Service Manual 808850

81

5 – Troubleshooting and System Tests

Table 6

All values can be ±10%.

CAUTION!

Do not use -VBUS (W) as ground. Doing so could destroy the power supply. Instead ground to either
the ground wire clip on the rear panel or to the heatsink. See Figure 5
on page 73.

J7 pin number to

ground

Test

Expected value

19

VACR (rectified AC line voltage)

0.86 V at 120 line voltage
1.87 V at 230 line voltage

21

VBUS (DC bus voltage)

2.28 VDC at 375 VBUS

18

IPFC (input current)

< 0.1 VDC

20

IFB (output current)

< 0.1 VDC

22

ITF (transfer current)

< 0.1 VDC

5

3.3 VDC

3.3 VDC ±10%

7

5 VDC

5 VDC ±10%

12

24 V sense pin

2.2 VDC ±10%

16

Start signal

3.2 VDC closed
0 VDC open

Advertising