Replace the air filter assembly – Hypertherm Powermax30 AIR Service Manual User Manual

Page 148

Advertising
background image

148

Powermax30 AIR Service Manual 808850

6 – Power Supply Component Replacement

Replace the air filter assembly

Remove the air filter assembly

1. Complete the following procedures:

a. Set the power switch to OFF (O), and disconnect the power cord from the power source.

b. See Remove the power supply cover on page 98.

2. Disconnect the drain hose

from the hole in the bottom of the power supply’s base. See

Figure 64.

It is normal to see water in the drain hose and in the air filter bowl. Remove any water that
spills inside the power supply before operating the system again.

3. Push-to-release the gas supply hose from the fitting on the right side of the air filter

. (See

How to use

push-to-connect fittings on page 133.)

4. Push-to-release the copper heat exchange coil from the fitting on the left side of the air filter

.

If you need better access to the air filter, remove the fan plenum

. Use a pair of

needlenose pliers to compress and release the plenum’s top 2 corner clips first before
working the bottom 2 clips free from the fan casing.

Figure 64

Kit number

Description

428375

Kit: Air filter assembly (includes gas hose, drain tube, and elbow fittings)

1

2

3

4

4

3

2

1

Advertising
This manual is related to the following products: