5 – Troubleshooting and System Tests

Control board LEDs

The control board (PCB1) is located inside of the front panel.

Figure 3

The control board has four diagnostic LEDs:

Reset – This LED illuminates when certain voltage readings to the power board are out of range. See Reset LED on
page 72.

Error – This LED illuminates when the internal compressor, torch cap, or temperature LEDs on the front of the power
supply illuminate. If all four LEDs on the front of the power supply are blinking, the Error LED also blinks. The number
of blinks between pauses indicates which component may have failed.

Transfer – This LED illuminates when there is proper arc transfer between the torch and the workpiece, and blinks
during continuous pilot arc operation (such as when cutting expanded metal or moving the arc off the plate and then
back on).

Start – This LED illuminates when the power supply receives a start signal and remains illuminated during normal
operation.

Control board

Ribbon cable