Replace the air filter bowl and air filter element

Remove the air filter bowl and air filter element

1. Complete the following procedures:

a. Set the power switch to OFF (O), and disconnect the power cord from the power source.

b. See Remove the power supply cover on page 98.

2. From the fan side of the power supply, disconnect the drain hose

from the fitting

at the bottom of the air filter

bowl.

It is normal to see water in the drain hose and in the air filter bowl. Remove any water that
spills inside the power supply before operating the system again.

If you need better access to the air filter, remove the fan plenum

. Use a pair of

needlenose pliers to compress and release the plenum’s top 2 corner clips first before
working the bottom 2 clips free from the fan casing.

3. Hold the top of the air filter assembly

steady with one hand. With your other hand, unscrew the air filter bowl

to

remove it.

Figure 66

Kit number

Description

428378

Kit: Air filter element

428380

Kit: Air filter bowl (includes air filter element, O-ring, and drain hose)