5 – Troubleshooting and System Tests

The power ON LED blinks.

Possible cause

Possible solution

The incoming voltage is below 90 VAC or
above 285 VAC.

Perform

Test 1 – voltage input on page 78.

All four LEDs blink when the system is
powered ON.

Possible causes

Possible solutions

A major fault has occurred in the power
supply. For example, the fan, solenoid valve,
control board, or power board may be faulty.

The error LED on the control board should
be blinking. The number of times it blinks
between pauses indicates which
components to test. See

Control board

LEDs on page 71.