Replace the trigger assembly – Hypertherm Powermax30 AIR Service Manual User Manual

Page 191

Advertising
background image

Powermax30 AIR Service Manual 808850

191

7 – Torch Component Replacement

9. Install the handle screws.

10. Pull the trigger to make sure it is positioned correctly in the torch handle.

11. Install the consumables.

12. Reconnect the power cord, and set the power switch to ON (I).

Replace the trigger assembly

1. Set the power switch to OFF (O), and disconnect the power cord from the power source.

2. Remove the consumables from the torch.

3. Place the torch on a flat surface with the left side of the handle facing up.

4. Remove the screws from the torch handle. Set the screws aside.

5. Being careful to keep the trigger spring from launching out of the handle, carefully pry the left side of the handle away

from the torch.

Kit

Description

428156

Kit: Torch trigger and spring

CAUTION!

Wear eye protection, as the trigger spring can launch out of the handle.

Advertising
This manual is related to the following products: