Hypertherm Powermax30 AIR Service Manual User Manual

Page 28

Advertising
background image

28

Powermax30 AIR Service Manual 808850

2 – Power Supply Setup

Determine the plasma system’s cutting power in watts by multiplying its maximum output amperage by its maximum rated
output voltage:

30 A × 83 VDC = 2,490 W (or 2.5 kW).

Table 1 – 120 V / 20 A

Table 2 – 120 V / 30 A

Table 3 – 200 V – 240 V / 16 A

Table 4 – 200 V – 240 V / 20 A

CAUTION!

A circuit capable of 120 V / 20 A or 240 V / 20 A is required for proper operation. Protect the circuit
with appropriately sized slow-blow (time-delay) fuses or circuit breakers.

Input voltage

120 V

Input current at rated output (19 A × 83 V = 1.6 kW)

19.2 A

Input current at arc stretch

37.5 A

Voltage tolerance

+10% / -10%

Input voltage

120 V

Input current at rated output (30 A × 83 V = 2.5 kW)

28.7 A

Input current at arc stretch

37.5 A

Voltage tolerance

+10% / -10%

Input voltage

200 V – 240 V

Input current at rated output (28 A × 83 V = 2.3 kW)

15.8 A – 13.4 A

Input current at arc stretch

37.5 A

Voltage tolerance

+10% / -10%

Input voltage

200 V – 240 V

Input current at rated output (30 A × 83 V = 2.5 kW)

16.7 A – 15.0 A

Input current at arc stretch

37.5 A

Voltage tolerance

+10% / -10%