Hypertherm Powermax30 AIR Service Manual User Manual

Page 79

Advertising
background image

Powermax30 AIR Service Manual 808850

79

5 – Troubleshooting and System Tests

Figure 10

6. If the AC voltage is incorrect, make sure you have power to the unit. If you do have power, inspect the power cord for

damage, and replace if necessary. See

Replace the power cord and strain relief on page 107.

7. If the power source and power cord are functioning correctly, disconnect the power cord again and reconnect the

two wires to the power switch.

8. Reconnect the electrical power and set the power switch to ON (I).

9. Measure the AC voltage from J1 to J2 (labeled “AC” on the back of the power board). This value should be the same

as the incoming line voltage. If it is not, check the power switch and replace if necessary. See

Replace the power

switch on page 116.

Figure 11

10. If the power-ON LED is still illuminated, perform Test 2 – power board voltage checks on page 80.

Single phase power supplies

Designator

CSA wire colors

CE wire colors

L (live)

Black

Brown

N (neutral)

White

Blue

PE (ground)

Green

Green/yellow

WORK LEAD (BLK)

AC

AC

R

w

TORCH

START

BLK

BLK

B

TORCH

START

N

L

PE

J1, J2 (AC)

Advertising
This manual is related to the following products: