6 – Power Supply Component Replacement

Replace the torch lead and strain relief

Remove the torch lead and strain relief

If you are replacing just the torch lead cable, not the whole torch assembly, refer to

Replace the torch lead on page 197

for details on how to remove the old lead from the torch.

1. Complete the following procedures:

a. Set the power switch to OFF (O), and disconnect the power cord from the power source.

b. See Remove the power supply cover on page 98.

c. See Detach the front panel on page 102.

2. Locate the 3-pin connector at the TORCH START slot (J12)

on the power board (on the side facing the heatsink)

where the orange, blue, and purple wires from the torch lead connect.

Figure 60

Kit number

Description

428176

Kit: Air T30 torch lead, 4.6 m (15 feet), with strain relief

1

WORK LEAD (BLK)

AC

AC

R

w

TORCH

START

BLK

BLK

B

TORCH

START

1