The page includes the following fields:

Basic Settings

Object

Description

Protocol Version

The STP protocol version setting. Valid values are STP, RSTP and MSTP.

Forward Delay

The delay used by STP Bridges to transition Root and Designated Ports to

Forwarding (used in STP compatible mode). Valid values are in the range 4 to 30

seconds

-Default:

15

-Minimum:

The higher of 4 or [(Max. Message Age / 2) + 1]

-Maximum:

30

Max Age

The maximum age of the information transmitted by the Bridge when it is the

Root Bridge. Valid values are in the range 6 to 200 seconds.

-Default:

20

-Minimum:

The higher of 6 or [2 x (Hello Time + 1)].

-Maximum:

The lower of 40 or [2 x (Forward Delay -1)]

Maximum Hop Count

This defines the initial value of remaining Hops for MSTI information generated at

the boundary of an MSTI region. It defines how many bridges a root bridge can

distribute its BPDU information. Valid values are in the range 6 to 40 hops.

Transmit Hold Count

The number of BPDU's a bridge port can send per second. When exceeded,

transmission of the next BPDU will be delayed. Valid values are in the range 1 to

10 BPDU's per second.

Advanced Settings

Object

Description

Edge Port BPDU

Filtering

Control whether a port explicitly configured as Edge will transmit and receive

BPDUs.

Edge Port BPDU Guard

Control whether a port explicitly configured as Edge will disable itself upon

reception of a BPDU. The port will enter the error-disabled state, and will be

removed from the active topology.

Port Error Recovery

Control whether a port in the error-disabled state automatically will be enabled

after a certain time. If recovery is not enabled, ports have to be disabled and

re-enabled for normal STP operation. The condition is also cleared by a system

reboot.

Port Error Recovery

Timeout

The time that has to pass before a port in the error-disabled state can be

enabled. Valid values are between 30 and 86400 seconds (24 hours).