4.2.19 Factory Default

You can reset the configuration of the stack switch on this page. Only the IP configuration is retained. The new configuration is

available immediately, which means that no restart is necessary. The Factory Default screen in

Figure 4-2-26

appears.

Figure 4-2-26 Factory Default page screenshot

Buttons

: Click to reset the configuration to Factory Defaults.

: Click to return to the Port State page without resetting the configuration.

After the “Factory” button be pressed and rebooted, the system will load the default IP settings as following:

Default IP address: 192.168.0.100

Subnet mask: 255.255.255.0

Default Gateway: 192.168.0.254

The other setting value is back to disable or none.

To reset the Managed Switch to the Factory default setting, you can also press the hardware reset button at

the front panel about 10 seconds. After the device be rebooted. You can login the management WEB

interface within the same subnet of 192.168.0.xx.

Hardware Reset button