Dimensions and ratings, Gv90, Boiler manual – Weil-McLain GV90+ User Manual

Page 101

Advertising
background image

Part number 550-142-054/0411

101

GV90+

gas

-

fired

water

boiler

— Boiler Manual

Figure 108

Boiler dimensional and physical data (see Figure 107, page 100)

Boiler

model

Supply

Return

Length

L

Gas

connection
size

(Note 1)

Electrical

service

required

(includes

the internal

circulators)

Boiler

water

content

Approx.

shipping

weight

(inches NPT

male)

(inches NPT

female)

(inches)

(inches NPT

female)

(amperes)

(gallons)

(pounds)

GV90+3

1

1

30¾

½

15

3.8

313

GV90+4

1

1

30¾

½

15

4.7

353

GV90+5

1

1

37¾

½

15

6.0

423

GV90+6

1

1

37¾

½

15

6.9

464

Note 1: Gas piping from meter to boiler to be sized per local utility requirements.

Figure 109

Boiler ratings

DOE

Boiler

model

CSA

Input

DOE

Heating

capacity

(Note 1)

Net I=B=R

water

rating

(Note 2)

AFUE

(Note 1)

Vent/

combustion

air diameter

Boiler

water

content

% Input derate vs vent length

(Values shown are at maximum vent/air pipe length)

(Note 3)

Direct Exhaust Venting

Direct Vent Venting

MBH

MBH

MBH

%

Inches

Gallons

Natural gas

Propane

Natural gas

Propane

GV90+3

70

65

56

91.9

3" PVC

3.8

up to 0.7%

up to 1.4%

up to 1.5%

up to 2.8%

GV90+4

105

97

84

91.2

3" PVC

4.7

up to 1.0%

up to 2.2%

up to 4.0%

up to 5.4%

GV90+5

140

130

113

91.4

3" PVC

6.0

up to 4.0%

up to 4.0%

up to 7.0%

up to 8.0%

GV90+6

175

161

140

91.0

3" PVC

6.9

up to 4.0%

up to 4.5%

up to 7.0%

up to 10.0%

Notes:

1. Based on standard test procedures prescribed by the United States Department of Energy. Ratings also

referred to as CSA Output. NOTE that only

DOE Heating Capacity and AFUE are certified by AHRI. AFUE is

also know as Annual Fuel Utilization Efficiency or Seasonal Efficiency.

2. Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building

and nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance
of 1.15 and are determined under the provisions governing forced draft boiler-burner units. An additional
allowance should be made for unusual piping and pickup loads.

3. All of the boilers will automatically de-rate as vent length increases, due to the pressure loss through the vent.

For vent/air pipe lengths less than the maximum, the derate equals the value above times vent length ÷ 100.

4. Boilers are tested for 50 PSIG working pressure.
5. GV90+ boilers are not available for millivolt systems.

Dimensions and ratings

(continued)